It’s time to automate

The standard for automated cell culture

RoboCell handles T-flasks, well plates, conical tubes and cryovials with incubation, centrifugation, imaging, media temperature control, label printing and third-party instrument integration — all under Bioflow control.

See a RoboCell run, module by module — how flasks move between incubation, liquid handling, imaging and counting, and how Bioflow keeps track of every step. Explore Bioflow

EFFICIENT

24/7 operation

Frees scientists from labor-intensive routine so they can focus on experiments, not feeding schedules.

CONSISTENT

Reproducible results

Standardized modules and processes treat every flask the same way, every time, with a complete digital record.

MODULAR

Scales with you

Add task modules or capacity as your production expands, without replacing the system you already have.

STERILE

Enclosed & safe

Fully enclosed positive- or negative-pressure enclosure with HEPA filtration protects cultures and operators.

Compare

Which RoboCell fits your lab?

Every configuration runs the same Bioflow software and the same task modules. Choose by labware, capacity and floor space — or lay one out yourself.

SpecificationRoboCell® Mito NewRoboCell® SmallRoboCell® MediumRoboCell® Large
Best forLabs wanting a compact, fully integrated first T-flask systemT-flask culturingT-flask and well-plate culturingHigh-capacity flask and plate culturing with cryogenic storage
LabwareT-flasksT-flasks, conical tubesT-flasks, well plates, conical tubesT-flasks, well plates, conical tubes, cryovials
Capacity128 T-flask storage · 8 heated + 4 ambient media lines · 5-flask processingPer configurationsee brochurePer configurationsee brochureHighest capacitysee brochure
Footprint2.5 × 2.3 m
8.2 × 7.5 ft
Compact enclosureExtended enclosureMulti-module enclosure
IncludedIncubation, storage, media processing, centrifugation, confluency, cell countingIncubation, liquid handling, media temperature control, microscopy, cell countingSmall + advanced liquid handler, well-plate incubationMedium + LN₂ refrigeration, controlled-rate freezing, individual cryovial handling, thawing
OptionsVi-CELL BLU counting, detachment, configurable below-deck modulesConical tube handling, centrifugation, plate dispensing, labelingCentrifugation, imaging, cryovial preparationAdditional storage and processing modules
SoftwareBioflow® on every configuration
Mito pageConfigureConfigureConfigure
RoboCell Small layout

RoboCell® Small

T-flask culturing with incubation, liquid handling, media temperature control, microscopy and cell counting.

RoboCell Medium layout

RoboCell® Medium

Adds well-plate culturing, an advanced liquid handler and plate incubation; optional centrifugation, imaging and cryovial preparation.

RoboCell Large layout

RoboCell® Large

Highest capacity with LN₂ refrigeration, controlled-rate freezing, individual cryovial handling and thawing in one end-to-end system.

Configure it yourself

Lay out your RoboCell around the linear robot

Pick a frame size to load its standard layout, then drag task modules to add, move or remove them anywhere along the rail. Everything is drawn to the same top-down scale. Nothing is saved — it is a sketch to talk through with our application scientists.

Linear robot rail
Request a quote for this layout
Modularity

20+ standard task modules

Each module runs inside RoboCell or as a stand-alone unit — same interfaces, same Bioflow control.

Robo-I Plus incubator
Robo-I™

Incubation

T-flask and plate incubators with on-board storage

Robo-S Plus ambient storage with cassette racks
Robo-S™

Storage

Ambient storage for flasks, plates and consumables

Robo-MR media module
Robo-MR™

Media supply

Heated and refrigerated media and reagent lines

Static stocker holding conical tubes, reservoirs and pipette tips
Static stocker

Consumables

Conical tubes, reservoirs and micropipette tips on demand

Gen-2 SCARA robot carrying a T-flask
Gen-2 SCARA

Transport

Rail-mounted SCARA moves labware between every module

T-flask decapper gripping a flask cap
T-flask decapper

Decapping

Removes and replaces caps without touching the flask neck

T-flask detacher tapping a flask
T-flask detacher

Detachment

Controlled tapping for even cell detachment

Celltrio Liquid Handler pipetting from a T-flask
Celltrio Liquid Handler

Liquid handling

Flask, tube and plate liquid handling

Robo-C centrifuge
Robo-C™

Centrifuge

Automated spin and decant for passage and harvest

Below-deck confluency microscope
Brightfield

Confluency

Imaging for passage decisions and records

Beckman Coulter Vi-CELL BLU inside RoboCell
Vi-CELL BLU

Cell counting

Beckman Coulter cell viability analyzer integration

Advanced plating module with Biomek i7
Advanced plating

Plating

6- to 1536-well plate formats

Static stocker interior holding flasks, plates and media
Storage & consumables

Labware in, cells out

Static and dynamic stockers hold flasks, plates, tubes and cryoracks in barcoded positions; the In & Out feed passes new labware into the enclosure without breaking the clean environment. Celltrio supplies validated consumables — cryovial racks, LabPorter™ tube carriers, media transfer tubing and reagent reservoirs — so every run starts from known-good parts.

  • Barcoded storage positions tracked in Bioflow
  • In & Out feed with SBS and T-175 formats
  • Validated consumables kits per protocol
Ask about consumables
Celltrio consumables

Validated labware for every module

Celltrio SBS-format cryovial rack with 96 cryovials
SBS format

Cryovial racks

96-position racks for RoboVial and RoboStor

Celltrio LabPorter rack holding six 50 mL conical tubes
LabPorter™

Conical tube racks

Barcoded carriers for 15 and 50 mL tubes

Celltrio serological pipettes in stocker cassettes
Celltrio

Pipettes

Serological pipettes in stocker-ready cassettes

Celltrio V-Groove Reservoir in sterile packaging
Automation friendly

V-Groove reservoirs

Sterile, non-pyrogenic, DNase/RNase free

Celltrio media transfer tubing and bag
Celltrio

Media tubing

Closed transfer sets for Robo-MR media lines

Facility & service

What procurement asks first

Sterility

Fully enclosed, positive- or negative-pressure enclosure with HEPA filtration; every process runs inside the sterile envelope.

Facility

Footprint, power, gas and LN₂ requirements are specified per configuration in the system brochure and site-prep guide.

Install & training

Site preparation review, installation, protocol onboarding and on-site operator training with every system.

Support

Ticketed support, remote diagnostics through Bioflow, and software updates for the life of the system.

Not sure which configuration? Send us your workflow.

We’ll map your labware, throughput and floor space to a RoboCell configuration.